- Make sure everything is all set in the exam room
- Take care of the patient, monitor him throughout the procedure
- Hygiene is an essential issue, both for the patient and for the staff
- Wash your hands often, wear gloves, mask and goggles, protective equipment, comply with universal precautions
- And, of course, good cooperation between doctor and nurse contributes to a successful procedure.
- Keep the snare tightly closed for 10-15 seconds
- Maintain full insufflation and avoid aspiration.
- Make sure the endoscope is straight.
- Angle the tip of the endoscope.
- Straighten and extend the catheter.
- Partially reopen the snare (about 1/3 of the snare handle; avoid fully opening). The goal is to open the snare wire just a little—enough to release the excess white ribbon of submucosa while keeping the snare "under" the lesion. It is important to avoid completely reopening the loop.
- Slowly lift the lesion off the colon wall.
- Be careful to release the trapped submucosa (a white band) under the lesion.
- Lower the lesion (to prevent its loss).
- Close the snare completely again to cut the lesion.
| Cold snare | Hot snare | |
| The position of the lesion | At 5 o'clock | At 5 o'clock |
| Margins normal tissue | Yes : at least 2 mm | Partial : minimum |
| Angulation | No : the snare sheath must remain anchored to the colon wall | Da : for applying electrocautery |
| Closing the snare | Continue until the cut is complete | Temporarily stopping when resistance is felt |
| Aspiration | No : insufflation is maintained | Yes |
| Electrocautery | No | Yes |